SoliStat options and configurations
SoliStat is not a single off-the-shelf part. The options below are what we have built before; our engineers can configure a SoliStat for a new application.

Voltage and amperage
Standard models switch any supply from 6 to 24 V, ideal for 12 V and 24 V systems; a 48 V model has been built for communications. Standard is 10 A, with 15 A, 20 A and 30 A models.
Channels and control
Single-channel models heat or cool; dual-channel models can do both. ON-OFF or fixed ON-time control, with PID on request.
Sensor
With the internal RTD, mount SoliStat directly on the part and it reads temperature through its own body. Or add an external thermocouple and mount the SoliStat elsewhere.
Programming
| Modes | Single channel: heating or cooling. Dual channel: also heat/cool. |
|---|---|
| ON-OFF control | Factory-programmable lower and upper trip points from −40°F to +257°F, minimum deadband 3.0°F |
| Fixed ON-time control | Factory-programmable trip point from −40°F to +257°F, ON-time in 1-second steps |
| PID | On request |
| Dual channel current | 5 A per channel with internal RTD; up to 10 A per channel with external sensors |
| Setpoint accuracy | Specified ±2.0°F. A lab test of 5 units found ±0.55°F (±0.30°C) average unit-to-unit variation, 1.2°F maximum. |
Electrical subsystems
- Bypass (shutdown) mode: power the heater off completely during idle periods, from a dash switch or the engine control unit.
- System ready and system fault lights: check the heating circuit at a glance.
- Fusing and crowbar circuit: power the system down automatically after a fault or a severe disturbance such as lightning.
- Multiple channels: run several heaters, or a heater and a cooler, from one controller.
Where SoliStat is already used
- Freeze prevention on diesel engine components, in ThermEvolve systems
- An autonomous climatology robot in Greenland
- Freeze prevention in remote oilfields
- DEF lines in diesel engines and locomotives
- Battery warmers for engines and outdoor machinery
- Water lines and water filters at remote solar sites
- Battery cabinets for electronics that work in the cold
- EGR filters in Tier IV diesel engines
Common questions
Can SoliStat run a heater and a cooler?
Yes, with a dual-channel model programmed for heat/cool.
Can I get it for 48 V?
Yes. A 48 V model has been built for communications applications; the HV-20 handles continuous voltages a bit above 48 V.
What happens if the controller is hit by lightning?
With fusing and the crowbar circuit, the monitoring system blows the fuse. Powering the controller off normally restores it, so a new fuse is likely the only repair.
More engenity products
- SoliStat DC thermostats
- SoliStat: weatherproof and rugged
- SoliStat: life testing
- How to order SoliStat
- IntelliHose C-DEF850M
- IntelliHose C-DEF11/1650M
- IntelliHose C-DEF2050M
- IntelliThaw PV200
- IntelliThaw PV400
- IntelliThaw MO-75
- Caterpillar genset catch can
- Caterpillar genset breather hoses
- ThermEvolve control
- IntelliHose heated hoses
- IntelliThaw heating jackets
Get a quote: SoliStat: options and configurations
Prefer to talk? Toll-free (844) 288-2590, local (612) 767-9590. To order standard parts, go through a distributor.
- The part: component or hose manufacturer and model number, and length.
- Power: supply voltage and the current the heater or load draws.
- Temperatures and quantity: setpoints you need and how many.