IntelliHose C-DEF850M heated DEF hose for Case 850M bulldozers
This IntelliHose model prevents freezing and slushing in the DEF lines of Case 850M bulldozers. It runs on 24 V straight from the engine battery.

What's in the assembly
Temperature control based on ThermEvolve technology, a heating element chosen for this hose, and durable insulation, on two EPDM hoses with SAE J2440 push-to-connect fittings.
Thaws in 3 minutes
In-house testing finds DEF in the hose warms from −40°F (−40°C) to liquid in 3 minutes at full duty power. After that the controller switches ON at 23°F and OFF at 27°F.
How to order
Standard IntelliHose models ship in 2 to 3 days in most cases. Order through a distributor, or contact us directly to discuss a sample.
- Voltage
- 24 V
- Full duty
- 9 W/ft · 182 W
- ON / OFF
- 23°F / 27°F
- Thaw from −40°F
- 3 min
Assembly specifications
| Built for | Case 850M bulldozers |
|---|---|
| Setpoints | ON at −5°C, OFF at −3°C (23°F, 27°F). DEF freezes at −11°C (12°F). |
| Time to thaw | DEF in the hose warms from −40°F (−40°C) to liquid (about 32°F, 0°C) in 3 minutes at full duty power (in-house testing). |
| Hoses | Two EPDM hoses (SAE 20R3EC) with SAE J2440 push-to-connect fittings |
| A hose | 3/8" inner diameter, 10 ft 3 in (312 cm) |
| B hose | 5/16" inner diameter, 10 ft (305 cm) |
| Voltage | 24 V nominal |
| Current draw, full duty | 375 mA/ft (1.23 A/m), 7.5 A total |
| Temperature maintenance | 0.18 duty (1.35 A total) at −40°F (−40°C); less at higher temperatures |
| Wattage, full duty | 9 W/ft (30 W/m), 182 W total |
| Electrical subsystems | As requested (bypass, ready and fault lights, fusing and crowbar) |
Detailed application notes are on the application notes and FAQ page.
Common questions
Which machines does the C-DEF850M fit?
It is built for Case 850M bulldozers. For other machines, an IntelliHose can be built to the hose, length and temperature you specify.
How much power does it draw once the DEF is liquid?
At −40°F it holds temperature at 0.18 duty, about 1.35 A in total. It draws less at higher temperatures.
Do I need to reprogram the engine control unit?
No. IntelliHose works on its own. Connect it to the equipment's power source, switched or unswitched.
More engenity products
- SoliStat DC thermostats
- SoliStat: weatherproof and rugged
- SoliStat: options and configurations
- SoliStat: life testing
- How to order SoliStat
- IntelliHose C-DEF11/1650M
- IntelliHose C-DEF2050M
- IntelliThaw PV200
- IntelliThaw PV400
- IntelliThaw MO-75
- Caterpillar genset catch can
- Caterpillar genset breather hoses
- ThermEvolve control
- IntelliHose heated hoses
- IntelliThaw heating jackets
Get a quote: IntelliHose C-DEF850M
Prefer to talk? Toll-free (844) 288-2590, local (612) 767-9590. To order standard parts, go through a distributor.
- The part: component or hose manufacturer and model number, and length.
- Power: supply voltage and the current the heater or load draws.
- Temperatures and quantity: setpoints you need and how many.