Built to stop thermostat burnouts

Comparable thermostats are often rated for 5,000 or 10,000 cycles and can be relied on for as little as 6 to 9 months. Two SoliStat units ran over 1,200,000 cycles at the extremes of their range, then over 3,000,000 at room temperature.

SoliStat life test rig with a digital cycle counter in the engenity lab

The test

One unit in a freezer at −40°F (−40°C), one in an oven at +257°F (+125°C), each switching a heater at 10 A (on 0.5 s, off 2.0 s), with a digital counter logging every cycle. Over a month of continuous switching, comparable to years in the field, with no failure.

Why bimetal fails on DC

A bimetal strip bends to touch a contact. On AC the switch often opens near a low point in the current, but on DC the current is constant, so it arcs every time. The arcing pits and corrodes the contact until it fails.

Why SoliStat doesn't

A transistor switches the current and an RTD reads temperature as resistance, not motion. No moving parts and no arcing means nothing inside to wear out, so SoliStat carries a 5-year limited warranty.

Rated cycles, typical bimetal
5,000 to 10,000
At −40°F and 257°F
1,200,000+
Then at room temperature
3,000,000+
Warranty
5 years
Fig. 1: a minimal heating system with a two-terminal bimetal thermostat on AC
Fig. 1: a minimal heating system with a two-terminal bimetal thermostat on AC
Fig. 3: the same system with a SoliStat on a DC source
Fig. 3: the same system with a SoliStat on a DC source

Common questions

How long does SoliStat last?

In our tests units ran over 3,000,000 cycles and were still working. It carries a 5-year limited warranty.

Why does a normal thermostat burn out on a battery?

On DC the current never drops to zero, so the bimetal contact arcs on every switch, pits and corrodes, and fails.

Can it be hermetically sealed?

Yes. Its solid-state parts allow a sealed construction that resists the elements.

Get a quote: SoliStat: life testing

Prefer to talk? Toll-free (844) 288-2590, local (612) 767-9590. To order standard parts, go through a distributor.

  1. The part: component or hose manufacturer and model number, and length.
  2. Power: supply voltage and the current the heater or load draws.
  3. Temperatures and quantity: setpoints you need and how many.

Call toll-freeGet a quote